PHE 1- or 2-Channel Inkjet Strip-chart Recorder

Part Number: PHE Brand: Fuji Electric Co, Ltd
Price
Request a Quote
Stock
Call for Pricing & Availablility

Fuji Electric offers the latest in low-cost inkjet recording with the PHE Inkjet Series Recorder.

This 100 mm recorder, built with polymer plastic mold technology to make it lightweight and durable, boasts many useful features.

The PHE, which is available in one or two channel recording, offers continuous Analog trending on the same axis which eliminates the phase shift syndrome exhibited by conventional pen recorders.

In addition, it has many digital printing capabilities-periodic data, scale line, alarm condition, burnout, and parameter printing.

Featuring an affordable inkjet print mechanism in a strip chart recorder, the PHE prints crisp, no-smudge characters without physical contact with the paper.

This printhead sprays the ink in tiny dots to create a trace in vivid colors for one or two channel continuous recording.

Utilizing a piezoelectric element, the PHE recorder creates stunning reports and print quality for the same price as a pen recorder.
Features
  • Inkjet printing technology without physical contact with the paper
  • Low-cost
  • Available in One or Two Channel continuous trace
  • Continuous Analog trending on the same axis
  • Many digital printing capabilities
  • Built with polymer plastic mold technology
  • The PHE Offers many of the features found in higher-priced instruments

Specifications

Accuracy

  • Chart Speed Accuracy: ± 0.1 %
  • Recording Accuracy (Indicating): ± 0.2 %
  • Reference Junction Compensation Accuracy (K, E, J, T, N, L, U, PN): ± 0.5° C (0.9° F)
  • Reference Junction Compensation Accuracy (R, S, B, W): ± 1° C (1.8° F)

Approvals & Certifications

  • CE
  • EMC - EN 50081-1 (1992), EN 50082-1 (1992)
  • IEC 1010-1 (1990)

Approvals & Certifications

  • ISO 9001

Consumption

  • Power (with Options): Approximately 15 VA at 100-120 Vac, 200-240 Vac
  • Power (without Options): Approximately 13 VA at 100-120 Vac, 200-240 Vac

Display

  • LED (7-Segment Alphanumeric, 10 mm High, 5 mm Wide), 6-Digits, Green

Electrical Connectors

  • Screw Terminals (M4 Thread)

Electrical Rating

  • 0.05 A at 12 Vdc
  • 3 A at 240 Vac (Resistive Load)
  • 3 A at 30 Vdc - Resistive Load

Enclosure, Body Material

  • Plastic Mold

Environmental Protection

  • IP50

Frequency

  • Supply Frequency: 50/60 Hz

Humidity

  • 20 to 80 % Relative Humidity, Non-Condensing
  • Chart Paper Influence: 65 % Relative Humidity
  • Chart Paper Influence: Contraction at 35 % Relative Humidity, 0.5 %, Max.
  • Chart Paper Influence: Expansion at 85 % Relative Humidity, 0.4 %, Max.

Hysteresis

  • Hysteresis Amplitude: 0.2 % of Recording Span

Input

  • 10-50 mA DC
  • 1-5 Vdc
  • 4-20 mA DC, Converted Into Voltage with 10 ohms or 250 ohms Shunt Resistor
  • -5 to 5 Vdc
  • -50 to 50 mVdc
  • -50 to 50 Vdc
  • -500 to 500 mVdc
  • DC Voltage Input (5 V, 50 V Range): ± 100 Vdc or Less - Max.
  • Thermocouple, RTD & DC Voltage (50 mV, 500 mV Range): ± 10 Vdc or Less - Max.
  • Thermocouple: 10 µV Per 100 ohms

Isolation

  • 100 megaohms (Between Each Terminal & Ground, at 500 Vdc)

Mounting

  • Panel Flush Mounting

Mounting Position

  • Front & Left/Right Inclination: 0°
  • Inclination Angle: 90° to 60° from Horizontal
  • Rear Inclination: 30°

Operating Temperature

  • 0° to 50° C (32° to 122° F)

Operating Voltages

  • 180-264 Vac
  • 85-132 Vac

Power Supply

  • 100-120 Vac
  • 200-240 Vac

Resistance

  • Input (5 V & 50 V Range): ≥ 1 Megaohm
  • Input (500 mV Range): ≥ 100 kiloohms
  • Input (Thermocouple, 50 mV Range): ≥ 10 megaohms
  • RTD: 10 ohms / Wire [Change in Indication: ± (0.1 % of Reference Range + 1-Digit) - Max.
  • Signal Source Resistance: 1 Kiloohm

Resolution

  • Recording Resolution: 0.1 mm

RTD Type

  • Pt100 ohm

Sensor, Probe Type

  • B Thermocouple
  • E Thermocouple
  • J Thermocouple
  • K Thermocouple
  • L Thermocouple
  • N Thermocouple
  • PN Thermocouple
  • RTD
  • R Thermocouple
  • S Thermocouple
  • T Thermocouple
  • U Thermocouple
  • W Thermocouple

Time Constant

  • Input Filter: 0 to 255 seconds

Vibration

  • 0.2 m/sec² (0.02 G) or Less, 10-60 Hz

Voltage

  • Withstand Voltage (Between Two Input Terminals, Input Terminal to Ground): 500 Vac, 1 Minute
  • Withstand Voltage (Power Terminal to Ground): 2,000 Vac, 1 Minute
show more