PHC Inkjet Strip Chart Recorder

Brand: Fuji Electric Co, Ltd

This recorder can record a maximum of 6 channels of DC voltage, mA, thermocouples and resistance bulbs.

The adoption of an ink jet system makes it possible to record measured data in Analog trace mode or to print in digital mode at a high speed.

This 100 mm-wide recorder performs recording clearly in 6 different colors.
Features
  • Compact size
  • High quality recording
  • Easy setting of input signals
  • Digital printing
  • Interactive key operation
  • Easy handling
  • Full variety of functions

1 model matching criteria
  • Recording Points - 3 Continuous Recording
  • Power Supply - 100-240 Vac, 50/60 Hz
  • Chart Paper - Without Chart Paper Illumination
  • Alarm Output / External Control - Without
  • Transmission Function - Without
Call for Pricing & Availablility
Does not ship to Massachusetts, United States

Specifications

Accuracy

  • Chart Speed Accuracy: ± 0.1 % (Expansion & Contraction of Paper is Not Included)
  • Clock Accuracy: ± 50 ppm or Less (Monthly Error, About 2 minutes)
  • Reference Junction Compensation (K, E, J, T, N, L, U, PN Thermocouple): ± 0.5° C (± 0.9° F)
  • Reference Junction Compensation (R, S, B, W Thermocouple): ± 1° C (± 1.8° F)
  • Thermocouple, Resistance Bulb, DC Voltage: ± (0.15 % + 1-Digit)
  • Thermocouple, RTD, DC Voltage: ± 0.25 % of Recording Span

Approvals & Certifications

  • EMC-Directive 89/336/EEC, EN 50081-1: -1992 (Conducted & Radiated Emissions), EN 50082-1: -1992 (Radiated Immunity, ESD & FBT)
  • UL 61010-1: 2001

Communication

  • Baud Rate: 2,400, 4,800, 9,600, 19,200 bit/sec
  • Binary Data Length: 8-bits, Parity: Odd/Even/None, Stop Bit: 1 or 2
  • RS-232
  • RS-232C
  • Start-Stop Synchronization
  • Transmission Method: Half-Duplex Bit Serial

Consumption

  • 100 Vac with All Options Approximately: 26 VA

Electrical Contacts

  • Normally Closed & Normally Open

Electrical Rating

  • Contact Capacity (UL): 1 A at 30 Vac/dc (Resistive Load)
  • Contact Capacity: 0.4 A at 125 Vac (Resistive Load), Normally Close
  • Contact Capacity: 2 A at 30 Vdc - Resistive Load, Normally Close
  • Contact Capacity: 3 A at 240 Vac / 30 Vdc - Resistive Load, Normally Open

Enclosure, Body Material

  • Steel Plate

Environmental Protection

  • Front: IEC IP50
  • Terminal: IP20

Function

  • Alarm
  • Recording Switch on Camera

Humidity

  • Chart Paper Influence (Contraction): 35 % Relative Humidity, 0.5 %, Max.
  • Chart Paper Influence (Expansion): 85 % Relative Humidity, 0.4 %, Max.
  • Operating Environment: 20 to 80 % Relative Humidity, Non-Condensing
  • Transportation/Storage Condition: 5 to 90 % Relative Humidity, Non-Condensing

Hysteresis

  • 0.5 % of Recording Span

Indication

  • Status Display Icon

Input

  • DC Voltage Input (5 V, 50 V Range): -100 to 100 Vdc or Less
  • Thermocouple, Resistance Bulb & DC Voltage (50 mV, 500 mV Range): -10 Vdc or Less

Input Signal

  • -50 to 50 V
  • -500 to 500 mV

Insulation Resistance

  • 100 megaohms or more (Between Each Terminal & Earth, at 500 Vdc)

Materials of Construction

  • Front Door Frame: Polycarbonate with Glass Wool

Mounting

  • Inclined up to 30° Backwards from the Vertical: Panel

Mounting Position

  • Front & Left/Right Inclination: 0°
  • Rear Inclination: 30°

Mounting Position Effect

  • Change in Indication: ± (0.1 % + 1-Digit) - Max.
  • Changing in Recording: ± 0.2 % of Recording Span, Max.

Operating Temperature

  • 0° to 50° C (32° to 122° F)

Output Noise

  • Common Mode Noise Rejection: 120 dB at 50, 60 Hz ± 0.1 Hz
  • Series Mode Noise Rejection: 30 dB at 50, 60 Hz ± 0.1 Hz

Power Supply

  • 100-240 Vac (10 %, ± 15 %), 50/60 Hz
  • 24 Vdc, ± 10 %

Power Supply Effect

  • Change in Indication: ± (0.1 % + 1-Digit) - Max.
  • Change in Recording: ± 0.2 % of Recording Span, Max.

Resistance

  • Input (5 V & 50 V): ≥ 1 Megaohm
  • Input (Thermocouple & 50 mV): > 10 megaohms
  • Iput (500 mV): > 100 kiloohms
  • Signal Source Resistance (Resistance Bulb Input): less than 10 ohms Per Line
  • Signal Source Resistance (Thermocouple Input): 1 Kiloohm or Less Voltage

Resistance Effect

  • Change in Indication (Thermocouple & RTD): ± (0.1 % + 1-Digit)
  • Change in Recording (Thermocouple & RTD): ± 0.2 % of Span
  • Voltage Input: 0.1 % Change of Resistance

Resolution

  • DC Voltage: 10 µA to 10 mA
  • Thermocouple, Resistance Bulb: 0.1° C
  • Thermocouple, RTD, DC Voltage: 0.1 mm Min.

RTD Type

  • Pt100 as Per IEN 60751

Sensor, Probe Type

  • B Thermocouple as Per EN 60584
  • C Thermocouple
  • D Thermocouple
  • E Thermocouple
  • J Thermocouple
  • K Thermocouple
  • L Thermocouple as Per DIN 43710
  • N Thermocouple
  • PN Thermocouple
  • RTD
  • R Thermocouple
  • S Thermocouple
  • T Thermocouple
  • U Thermocouple as Per DIN 43710

Storage Temperature

  • -10° to 60° C (14° to 140° F)

Supply Voltage

  • Withstand Voltage: between Alarm Terminals 750 Vac for 1 Minute
  • Withstand Voltage: Input Terminal - Input Terminal, Input Terminal - Ground, Power Terminal - Input Terminal 500 Vac for 1 Minute
  • Withstand Voltage: Power Supply Terminal - Ground 2,000 Vac for 1 Minute

Temperature Effect

  • Change in Indication: ± (0.3 % + 1-Digit)/10° C, Max.
  • Change in Recording: ± 0.5 %/10° C (18° F) - Max.

Temperature Range

  • RTD: -200° to 600° C (-328° to 1,112° F)
  • Thermocouple: -200° to 1,760° C (-328° to 3,200° F)

Terminal Strip

  • External Terminals: Screw Terminal Strip (M4 Screws)

Update Time

  • Warm-Up Time: 30 minutes or Less

Vibration

  • Operating Environment: 10-60 Hz, 0.2 m/sec² (0.02 G) or Less
  • Transportation/Storage Condition: 2.45 m/sec² (0.25 G), 10-60 Hz

Vibration Effect

  • Change in Indication: ± (0.1 % + 1-Digit) - Max.
  • Change in Recording: ± 0.2 % of Recording Span, Max.

show more