F030 Batch Controller
Brand: Precision Digital CorporationThe F030 is a straight forward but basic Batch Controller.
The operator can enter a batch quantity easily or execute repeating batches.
During the batch, the preset value is displayed as well as the batched (or remaining) quantity and the units of measurement.
The automatic self-learning overrun correction will ensure an accurate result each batch again.
A wide selection of options further enhances the capabilities of this model, including Intrinsic Safety.
Features- Large display shows preset value and running batch value simultaneously
- LED backlight option
- Count-up and count-down function available
- Selectable on-screen engineering units; volumetric or mass
- Self-learning overrun correction
- Easy operation to enter a batch value and to control the process
- Ability to process all types of signals: Sine wave (coil), NAMUR, NPN/PNP pulse, Reed-switch, Active pulse signals, (0)4-20 mA
- One control output for one-stage batching
- Power requirements: Input loop powered, battery powered or 8 - 30 VDC, 24VAC/DC and 115 - 230VAC
- Sensor supply: 3.2 / 8.2 / 12 / 24 VDC
- Auto backup of settings and running totals
- Explosion/flame proof available, according ATEX/IECEx
Advantages
- Robust aluminum or stainless steel 316L field enclosure (IP67/ NEMA Type4X). It is so rugged, a truck can even stand on it!
- Intrinsically Safe available - ATEX, IECEx, FM and CSA approval for gas and dust applications
- Programming can be done by your own crew, with the sensible menu-driven structure, saving cost and irritation. Know one, know them all!
- Very diverse mounting possibilities: walls, pipes, panels or directly onto outdoor sensors!
Displaying prices & availability for Ohio, United States in USD. Change location.
Models matching criteria: 8,892
- Input - Pulse Input
- Enclosure - Aluminum, Wall Mount, Cable Entry: 3 x .5” NPT
- Output Options - One Passive Transistor Output - Standard Configuration
- Power Supply - 24 Vac/ Vdc + Sensor Supply
- Relay - Backlight
Call for Pricing & Availablility
Does not ship to OH, United States
- Input - 0-10 Vdc
- Enclosure - Panel Mount, Aluminum
- Output Options - One Passive Transistor Output - Standard Configuration
- Power Supply - Lithium Battery Powered
- Hazardous Area - Safe Area Only
- Relay - Coil Input 5 mVpp
Call for Pricing & Availablility
Does not ship to OH, United States
- Input - Pulse Input
- Enclosure - Aluminum, Wall Mount, Cable Entry: 2 x 1/2” NPT
- Output Options - One Passive Transistor Output - Standard Configuration
- Power Supply - 115-230 Vac + Sensor Supply
- Relay - Coil Input 10 mVpp
Call for Pricing & Availablility
Does not ship to OH, United States
- Input - Pulse Input
- Enclosure - GRP, Wall Mount, Cable Entry: 3 x Ø 22 mm
- Output Options - One Passive Transistor Output - Standard Configuration
- Power Supply - 115-230 Vac + Sensor Supply
- Hazardous Area - Safe Area Only
- Relay - Backlight
Call for Pricing & Availablility
Does not ship to OH, United States
- Input - Pulse Input
- Enclosure - Aluminum, Wall Mount, Cable Entry: 4 x M20
- Output Options - One Passive Transistor Output - Standard Configuration
- Power Supply - Lithium Battery Powered - Intrinsically Safe
- Hazardous Area - Intrinsically Safe According ATEX, IECEx, CSA c-us, & FM
- Relay - Coil Input 10 mVpp
Call for Pricing & Availablility
Does not ship to OH, United States
- Input - 0-10 Vdc
- Enclosure - Aluminum, Wall Mount, Cable Entry: 2 x M20
- Output Options - One Passive Transistor Output - Standard Configuration
- Power Supply - Lithium Battery Powered
- Hazardous Area - EExd Enclosure - 3 Micro-Switch Keys
- Relay - Coil Input 10 mVpp
Call for Pricing & Availablility
Does not ship to OH, United States
- Input - 0-10 Vdc
- Enclosure - GRP, Wall Mount, Flat Bottom, Cable Entry: No Holes
- Output Options - One Mechanical Relay Output
- Power Supply - 24 Vac/ Vdc + Sensor Supply
- Hazardous Area - EExd Enclosure - 3 Micro-Switch Keys
- Relay - Coil Input 5 mVpp
Call for Pricing & Availablility
Does not ship to OH, United States
- Input - 4-20 mA
- Enclosure - Aluminum, Wall Mount, Cable Entry: 2 x M16 + 1 x M20
- Output Options - One Active Transistor Output
- Power Supply - 24 Vac/ Vdc + Sensor Supply
- Hazardous Area - EExd Enclosure - 3 Micro-Switch Keys
- Relay - Coil Input 10 mVpp
Call for Pricing & Availablility
Does not ship to OH, United States
- Input - Pulse Input
- Enclosure - Aluminum, Wall Mount, Cable Entry: 2 x 1/2” NPT
- Output Options - One Mechanical Relay Output
- Power Supply - 24 Vac/ Vdc + Sensor Supply
- Hazardous Area - EExd Enclosure - 3 Micro-Switch Keys
- Relay - Coil Input 10 mVpp
Call for Pricing & Availablility
Does not ship to OH, United States
- Input - 4-20 mA
- Enclosure - Aluminum, Wall Mount, Cable Entry: 2 x 1/2” NPT
- Output Options - One Mechanical Relay Output
- Power Supply - 24 Vac/ Vdc + Sensor Supply
- Hazardous Area - EExd Enclosure - 3 Micro-Switch Keys
- Relay - Coil Input 10 mVpp
Call for Pricing & Availablility
Does not ship to OH, United States
- Input - Pulse Input
- Enclosure - GRP, Wall Mount, Flat Bottom, Cable Entry: No Holes
- Output Options - One Passive Transistor Output - Standard Configuration
- Power Supply - Input Loop-Powered from Sensor Signal 4-20 mA
- Hazardous Area - Safe Area Only
- Relay - Coil Input 5 mVpp
Call for Pricing & Availablility
Does not ship to OH, United States
- Input - 4-20 mA
- Enclosure - GRP, Wall Mount, Cable Entry: 1 x Ø 22 mm
- Output Options - One Mechanical Relay Output
- Power Supply - 115-230 Vac + Sensor Supply
- Hazardous Area - Safe Area Only
- Relay - No Options
Call for Pricing & Availablility
Does not ship to OH, United States
- Input - Pulse Input
- Enclosure - Aluminum, Wall Mount, Cable Entry: 2 x 1/2” NPT
- Output Options - One Mechanical Relay Output
- Power Supply - 24 Vac/ Vdc + Sensor Supply
- Hazardous Area - Safe Area Only
- Relay - Coil Input 5 mVpp
Call for Pricing & Availablility
Does not ship to OH, United States
- Input - 0-10 Vdc
- Enclosure - GRP, Wall Mount, Cable Entry: 2 x Ø 16 mm & 1 x Ø 20 mm
- Output Options - One Passive Transistor Output - Standard Configuration
- Power Supply - Lithium Battery Powered - Intrinsically Safe
- Hazardous Area - Safe Area Only
- Relay - Backlight
Call for Pricing & Availablility
Does not ship to OH, United States
- Input - 0-10 Vdc
- Enclosure - Aluminum, Wall Mount, Cable Entry: No Holes
- Output Options - One Passive Transistor Output - Standard Configuration
- Power Supply - 24 Vac/ Vdc + Sensor Supply
- Hazardous Area - Safe Area Only
- Relay - Backlight
Call for Pricing & Availablility
Does not ship to OH, United States
- Input - 0-10 Vdc
- Enclosure - Aluminum, Wall Mount, Cable Entry: 2 x M20
- Output Options - One Active Transistor Output
- Hazardous Area - EExd Enclosure - 3 Micro-Switch Keys
- Relay - Backlight
Call for Pricing & Availablility
Does not ship to OH, United States
- Input - Pulse Input
- Enclosure - GRP, Wall Mount, Cable Entry: No Holes
- Output Options - One Mechanical Relay Output
- Power Supply - 115-230 Vac + Sensor Supply
- Hazardous Area - Safe Area Only
- Relay - Coil Input 10 mVpp
Call for Pricing & Availablility
Does not ship to OH, United States
- Input - 4-20 mA
- Enclosure - Aluminum, Wall Mount, Cable Entry: 2 x M16 + 1 x M20
- Output Options - One Mechanical Relay Output
- Power Supply - 24 Vac/ Vdc + Sensor Supply
- Hazardous Area - Safe Area Only
- Relay - Backlight
Call for Pricing & Availablility
Does not ship to OH, United States
- Input - 0-10 Vdc
- Enclosure - GRP, Wall Mount, Cable Entry: 3 x Ø 22 mm
- Output Options - One Passive Transistor Output - Standard Configuration
- Power Supply - Input Loop-Powered from Sensor Signal 4-20 mA
- Hazardous Area - EExd Enclosure - 3 Micro-Switch Keys
- Relay - Coil Input 10 mVpp
Call for Pricing & Availablility
Does not ship to OH, United States
- Input - 4-20 mA
- Enclosure - Panel Mount, GRP
- Output Options - One Active Transistor Output
- Hazardous Area - Safe Area Only
- Relay - Backlight
Call for Pricing & Availablility
Does not ship to OH, United States
- Input - Pulse Input
- Enclosure - Aluminum, Wall Mount, Cable Entry: 2 x M16 + 1 x M20
- Output Options - One Passive Transistor Output - Standard Configuration
- Power Supply - Lithium Battery Powered
- Hazardous Area - Safe Area Only
- Relay - Coil Input 10 mVpp
Call for Pricing & Availablility
Does not ship to OH, United States
- Input - Pulse Input
- Enclosure - GRP, Wall Mount, Cable Entry: 2 x Ø 20 mm
- Output Options - One Passive Transistor Output - Standard Configuration
- Power Supply - Basic Power Supply 8-30 Vdc
- Hazardous Area - EExd Enclosure - 3 Micro-Switch Keys
- Relay - Coil Input 5 mVpp
Call for Pricing & Availablility
Does not ship to OH, United States
- Input - 4-20 mA
- Enclosure - GRP, Wall Mount, Cable Entry: No Holes
- Output Options - One Mechanical Relay Output
- Power Supply - 115-230 Vac + Sensor Supply
- Hazardous Area - EExd Enclosure - 3 Micro-Switch Keys
- Relay - Backlight
Call for Pricing & Availablility
Does not ship to OH, United States
- Input - 0-10 Vdc
- Enclosure - GRP, Wall Mount, Flat Bottom, Cable Entry: No Holes
- Output Options - One Active Transistor Output
- Hazardous Area - EExd Enclosure - 3 Micro-Switch Keys
- Relay - No Options
Call for Pricing & Availablility
Does not ship to OH, United States
- Input - 0-10 Vdc
- Enclosure - Panel Mount, GRP
- Output Options - One Passive Transistor Output - Standard Configuration
- Power Supply - 115-230 Vac + Sensor Supply
- Hazardous Area - EExd Enclosure - 3 Micro-Switch Keys
- Relay - Coil Input 5 mVpp
Call for Pricing & Availablility
Does not ship to OH, United States
- Input - 0-10 Vdc
- Enclosure - Aluminum, Wall Mount, Cable Entry: 2 x PG9 + 1 x M20
- Output Options - One Passive Transistor Output - Standard Configuration
- Power Supply - 115-230 Vac + Sensor Supply
- Hazardous Area - Safe Area Only
- Relay - Coil Input 5 mVpp
Call for Pricing & Availablility
Does not ship to OH, United States
- Input - 0-10 Vdc
- Enclosure - Aluminum, Wall Mount, Cable Entry: 4 x M20
- Output Options - One Passive Transistor Output - Standard Configuration
- Power Supply - 16-30 Vdc + Sensor Supply
- Hazardous Area - Intrinsically Safe According ATEX, IECEx, CSA c-us, & FM
- Relay - Backlight
Call for Pricing & Availablility
Does not ship to OH, United States
- Input - 4-20 mA
- Enclosure - Aluminum, Wall Mount, Cable Entry: 1 x .5” NPT
- Output Options - One Mechanical Relay Output
- Power Supply - 24 Vac/ Vdc + Sensor Supply
- Hazardous Area - Safe Area Only
- Relay - Coil Input 5 mVpp
Call for Pricing & Availablility
Does not ship to OH, United States
- Input - Pulse Input
- Enclosure - Aluminum, Wall Mount, Cable Entry: 1 x M20
- Output Options - One Passive Transistor Output - Standard Configuration
- Power Supply - Lithium Battery Powered
- Relay - Coil Input 10 mVpp
Call for Pricing & Availablility
Does not ship to OH, United States
- Input - 4-20 mA
- Enclosure - Aluminum, Wall Mount, Cable Entry: 1 x M20
- Output Options - One Mechanical Relay Output
- Power Supply - 24 Vac/ Vdc + Sensor Supply
- Relay - No Options
Call for Pricing & Availablility
Does not ship to OH, United States
- Input - 0-10 Vdc
- Enclosure - GRP, Wall Mount, Cable Entry: 3 x Ø 22 mm
- Output Options - One Passive Transistor Output - Standard Configuration
- Power Supply - Basic Power Supply 8-30 Vdc
- Hazardous Area - EExd Enclosure - 3 Micro-Switch Keys
- Relay - Coil Input 5 mVpp
Call for Pricing & Availablility
Does not ship to OH, United States
- Input - Pulse Input
- Enclosure - Panel Mount, Aluminum
- Output Options - One Passive Transistor Output - Standard Configuration
- Power Supply - Lithium Battery Powered - Intrinsically Safe
- Hazardous Area - Safe Area Only
- Relay - Coil Input 5 mVpp
Call for Pricing & Availablility
Does not ship to OH, United States
- Input - Pulse Input
- Enclosure - Aluminum, Wall Mount, Cable Entry: 3 x .5” NPT
- Output Options - One Passive Transistor Output - Standard Configuration
- Power Supply - Basic Power Supply 8-30 Vdc
- Hazardous Area - Safe Area Only
- Relay - Coil Input 5 mVpp
Call for Pricing & Availablility
Does not ship to OH, United States
- Input - 4-20 mA
- Enclosure - Aluminum, Wall Mount, Cable Entry: 2 x M16 + 1 x M20
- Output Options - One Passive Transistor Output - Standard Configuration
- Power Supply - Input Loop-Powered from Sensor Signal 4-20 mA
- Hazardous Area - Intrinsically Safe According ATEX, IECEx, CSA c-us, & FM
- Relay - Coil Input 5 mVpp
Call for Pricing & Availablility
Does not ship to OH, United States
- Input - 4-20 mA
- Enclosure - Aluminum, Wall Mount, Cable Entry: 2 x M20
- Output Options - One Passive Transistor Output - Standard Configuration
- Power Supply - Lithium Battery Powered - Intrinsically Safe
- Hazardous Area - Safe Area Only
- Relay - Coil Input 10 mVpp
Call for Pricing & Availablility
Does not ship to OH, United States
- Input - Pulse Input
- Enclosure - Panel Mount, GRP
- Output Options - One Mechanical Relay Output
- Relay - Backlight
Call for Pricing & Availablility
Does not ship to OH, United States
- Input - 4-20 mA
- Enclosure - Aluminum, Wall Mount, Cable Entry: 2 x M16 + 1 x M20
- Output Options - One Passive Transistor Output - Standard Configuration
- Power Supply - Lithium Battery Powered - Intrinsically Safe
- Hazardous Area - Safe Area Only
- Relay - Coil Input 5 mVpp
Call for Pricing & Availablility
Does not ship to OH, United States
- Input - 0-10 Vdc
- Enclosure - Aluminum, Wall Mount, Cable Entry: 2 x 1/2” NPT
- Output Options - One Passive Transistor Output - Standard Configuration
- Power Supply - Basic Power Supply 8-30 Vdc
- Hazardous Area - Safe Area Only
- Relay - Backlight
Call for Pricing & Availablility
Does not ship to OH, United States
- Input - 0-10 Vdc
- Enclosure - Panel Mount, GRP
- Output Options - One Active Transistor Output
- Hazardous Area - EExd Enclosure - 3 Micro-Switch Keys
- Relay - No Options
Call for Pricing & Availablility
Does not ship to OH, United States
- Input - 0-10 Vdc
- Enclosure - Aluminum, Wall Mount, Cable Entry: 2 x M20
- Output Options - One Mechanical Relay Output
- Power Supply - 115-230 Vac + Sensor Supply
- Relay - Backlight
Call for Pricing & Availablility
Does not ship to OH, United States
Specifications
Accuracy
- Error < 0.01 mA / ± 0.05 % Full Scale.
Approvals & Certifications
- IP/NEMA
- RoHS
- ATEX
- CE
- CSA
- EMC
- FM
- IEC
- IECEx
Conduit Connection
- 1/2" NPT
- M12
- M16
- M20
- PG9
Enclosure Material
- Field: 316 Stainless Steel
- Polycarbonate Window
- Sealing: Silicone
- Field: Aluminum
Environmental Protection
- IP65
- IP67
- NEMA 4X / IP65, 67
K-Factor
- 0.000010 to 9,999,999
Operating Temperature
- -40° to 80° C (-40° to 176° F)
Power
- 115-230 Vac
- 8-24 Vac/Vdc
Resolution
- 16-bits
Terminal Connection
- Removable Plug-In Terminal Strip
Voltage Drop
- 1 VDC at 20 mA
- max. 2.6 Vdc @ 20 mA (Loop-Powered)
- For One Stage Batch Qpplications at Low or Medium Flow Rates with Single or Repeating Batches
- Field Mount Indicators in Safe and Hazardous Area Applications. Especially in Harsh Weather Conditions Like Rain, Snow, Sandy Deserts, Salty Atmospheres and Temperatures Between -40° to +80° C (-40° to 176° F)