PD6626-L3N

Price
Request a Quote
Stock
Call for Pricing & Availablility

  • Product Type: 1/8 DIN Loop-Powered Flow Rate/Totalizer Digital Panel Meter
  • Inputs: Current (4-20 mA)
  • Outputs: (2) Open Collectors, (1) 4-20 mA Output
  • Display: Dual Line, 0.7" & 0.4" High, 5 & 8 Digits, Decimal, LCD
  • Backlight: Standard / Red on Alarm
  • Approvals: ATEX (IS), CE, UL/C-UL, IEC (IS), UL/C-UL (IS, NI)
  • Warranty: 3 years

Specifications

Display

  • Dual-line LCD with backlight
  • Both lines 14-segment alphanumeric
  • Top: 2.8" / 71 mm, 5 digits
  • Bottom: 1.5" / 39 mm, 8 characters
  • Display may be programmed to turn red and flash a user-defined message on alarm condition

Programming Method

  • Front panel & Free PC-based USB programming software

Enclosure & Materials

  • Enclosure: 1/8 DIN, IP65, NEMA 4X front panel, high impact plastic, NORYL® polyphenylene ether & polystyrene blend (PPE PS) resin, UL 94V-0, Color: gray
  • Gasket: Silicone Rubber
  • Faceplate: LEXAN® polycarbonate (PC) Film
  • Buttons: Silicone rubber

Noise Filter

  • Averages the input signal over a period of time between 1 and 16 seconds to dampen the effects of a noisy signal that causes a jumpy display

Tightening Torque

  • Screw terminal connectors: 4.5 lb-in (0.5 Nm)
  • Mounting screws: 8.0 lb-in max. (0.9 Nm)

Operating Temperature

  • -40° to 70° C

Storage Temperature

  • -40° to 85° C

Relative Humidity

  • 0 to 90 % Non-condensing

Connections

  • Removable screw terminals accept 12 to 22 AWG wire

Accuracy

  • ± 0.02 % of span ± 1 count
  • Square root and programmable exponent: 10-100 % Full Scale

Overall Dimensions (W x H x D)

  • 4.68" x 2.45" x 3.79" (119 mm x 62 mm x 96 mm)

Weight

  • 8.7 oz. - 247 g with option board

Warranty

  • 3 Years Parts and Labor

Approvals

  • ATEX: II 1G, Ex ia IIC T4 Ga, Ta = -40° to +70° C Certificate Number: CML 17ATEX2015X
  • IECEx: Ex ia IIC T4 Ga, Tamb = -40° to +70° C Certificate Number: IECEx CML 17.0008X
  • UL & cUL Listed as Intrinsically Safe and Nonincendive: Class I, Div. 1, Groups A, B, C and D T4, Class I, Div. 2, Groups A, B, C and D T4 Ex ia IIC T4 (Canada), Class I Zone 0, Zone 1 AEx ia IIC T4 (U.S.) Class I Zone 2, Group IIC T4 (U.S.) PROCESS CONTROL EQUIPMENT FOR USE IN HAZARDOUS LOCATIONS
  • EMC
show more