PD6830 ProtEX-RTP Explosion-Proof Pulse Input Flow Rate/Totalizer

Brand: Precision Digital Corporation

The ProtEX-RTP PD6830 is a rugged, explosion-proof, pulse input rate/totalizer for demanding applications in hazardous areas.

It can be powered from 9-30 VDC, battery, or from the 4-20 mA output loop; includes two isolated open collector pulse outputs and is available with an isolated RS-485 option for Mod-bus communications.

The instrument will operate over a temperature range of -40 to 75°C (-40 to 167°F).

The PD6830 carries major approvals including:

  • CSA Certified as Explosion-Proof / Dust Ignition-Proof / Flame-Proof
  • ATEX and IECEx Certified as Flame-Proof and Protection by Enclosure

The top numeric display will read rate or total up to five digits and the alphanumeric bottom display will read up to 7 digits, 13 digits with the total overflow feature.

The alphanumeric display can also be pro-grammed to show any combination of numbers and letters up to seven characters long for rate, total, grand total, engineering units and/or identification tag.

The backlight makes the display more visible in any lighting condition. The enclosure is provided with threaded conduit holes and integrated pipe or wall mounting flanges.

Free, PC-based, MeterView EX software that connects to the meter via the PDA8068, PDA7485-I, or the PDA8485-I is available for programming and setup of the instrument.

Features
  • Fully-Approved Explosion-Proof Pulse Input Rate/Totalizer
  • Pulse, Open Collector, NPN, PNP, TTL, Switch Contact, Sine Wave (Coil), Square Wave, Isolated Inputs
  • 0.7" (17.8 mm) 5 Digits Upper Display for Rate or Total
  • 0.4" (10.2 mm) 7 Alphanumeric Characters Lower Display for Rate, Total, Grand Total, Units, and Tag
  • Display Mountable at 0°, 90°, 180°, & 270°
  • SafeTouch Through-Glass Button Programming
  • 13-Digit Totalizer with Total Overflow Feature
  • Gate Function for Rate Display of Slow Pulse Rates
  • K-Factor, Scaling, or Live Input Calibration with 32-Point Linearization
  • Automatic Rate, Total, and Grand Total Unit Conversions
  • Backlight Standard on All Models
  • Isolated 4-20 mA Output for Rate, Total, or Grand Total
  • Two Isolated Open Collector Pulse Outputs, Up to 5 kHz
  • Battery, DC, or Output Loop-Powered Models
  • Operating Temperature Range: -40 to 75°C (-40 to 167°F)
  • CSA Certified as Explosion-Proof / Dust-Ignition Proof / Flame-Proof
  • ATEX and IECEx Certified as Flame-Proof and Protection by Enclosure
  • Conformal Coated PCBs for Dust and Humidity Protection
  • Password Protection
  • On-Board Data Logging of up to 1024 points
  • Free Meterview EX Programming Software
  • Modbus Communications Isolated RS-485 Option
  • Wide Viewing Angle
  • Flanges for Wall or Pipe Mounting
  • Explosion-Proof, IP68, NEMA 4X Die-Cast Aluminum Enclosure
  • Three 3/4" NPT Threaded Conduit Openings (One Plug Installed)
  • 2" U-Bolt Kits Available
  • Stainless Steel Tag Available
  • 3-Year Warranty

Models matching criteria: 14
  • Power Type - Battery Powered
  • Loop Output - With
  • Options - Isolated Signal 2-Wire RS-485 with Modbus Protocol
Call for Pricing & Availablility
Does not ship to OH, United States
  • Power Type - DC Powered
  • Loop Output - Without
  • Options - None
Call for Pricing & Availablility
Does not ship to OH, United States
  • Power Type - Battery Powered
  • Loop Output - Without
  • Options - None
Call for Pricing & Availablility
Does not ship to OH, United States
  • Power Type - Output Loop Powered
  • Loop Output - With
  • Options - Isolated Signal 2-Wire RS-485 with Modbus Protocol
Call for Pricing & Availablility
Does not ship to OH, United States
  • Power Type - Battery Powered
  • Loop Output - With
  • Options - None
Call for Pricing & Availablility
Does not ship to OH, United States
  • Power Type - DC Powered
  • Loop Output - With
  • Options - Isolated Signal 2-Wire RS-485 with Modbus Protocol
Call for Pricing & Availablility
Does not ship to OH, United States
  • Power Type - DC Powered
  • Loop Output - Without
  • Options - Isolated Signal 2-Wire RS-485 with Modbus Protocol
Call for Pricing & Availablility
Does not ship to OH, United States
  • Power Type - Output Loop Powered
  • Loop Output - With
  • Options - None
Call for Pricing & Availablility
Does not ship to OH, United States
  • Power Type - Battery Powered
  • Loop Output - With Loop Output & Output Loop Powered Backlight
  • Options - None
Call for Pricing & Availablility
Does not ship to OH, United States
  • Power Type - DC Powered
  • Loop Output - With
  • Options - None
Call for Pricing & Availablility
Does not ship to OH, United States
  • Power Type - Output Loop Powered
  • Loop Output - With Loop Output & Battery Backup
  • Options - Isolated Signal 2-Wire RS-485 with Modbus Protocol
Call for Pricing & Availablility
Does not ship to OH, United States
  • Power Type - Battery Powered
  • Loop Output - With Loop Output & Output Loop Powered Backlight
  • Options - Isolated Signal 2-Wire RS-485 with Modbus Protocol
Call for Pricing & Availablility
Does not ship to OH, United States
  • Power Type - Battery Powered
  • Loop Output - Without
  • Options - Isolated Signal 2-Wire RS-485 with Modbus Protocol
Call for Pricing & Availablility
Does not ship to OH, United States
  • Power Type - Output Loop Powered
  • Loop Output - With Loop Output & Battery Backup
  • Options - None
Call for Pricing & Availablility
Does not ship to OH, United States

Specifications

Display

  • Top: Five Digits (0 to 99,999), 0.7" (17.8 mm) high, 7-segment, automatic Lead Zero Blanking
  • Bottom: Seven alphanumeric characters, 0.4" (10.2 mm) high, 14-segment, automatic lead zero blanking
  • Symbols: Total, grand total, battery power/low battery, high alarm, low alarm, SafeTouch button sleep mode/disable, password lock

Display Assignment

  • Top Display: Rate or total
  • Bottom Display: Combinations of rate, total, grand total, units, and custom tag

Backlight

  • White; it can be disabled/enabled in the Advanced - System menu
  • The backlight is automatically turned off below -20°C

Programming Method

  • Four SafeTouch through-glass buttons when cover is installed
  • Four internal pushbuttons when cover is removed. Free MeterView EX software

Display Orientation

  • Display may be mounted at 90° increments up to 270° from default orientation

Approvals & Certifications

  • IECEx
  • CE
  • ATEX
  • CSA

Alarm Indication

  • Flashing display plus HI/LO (rate) or SET (total) indicators

Power Options

  • 9-30 VDC Powered, 2.2 W max
  • 4-20 mA Output Powered, 30 VDC max
  • Battery Power
  • 9-30 VDC Powered with Battery Backup
  • 4-20 mA Output Powered with Battery Backup

Battery

  • 3.6 V Primary Lithium (Li-SOCl2), non-rechargeable Model PDABAT36C

Isolation

  • All models: 500 V opto-isolated input-to-power/output with isolated input enabled
  • PD6830-BTA: 500 V input-to-output
  • PD6830-APA: 500 V input/power-to-output

Data Logging

  • Up to 1024 records, recorded 4/day at Specific times or at defined time intervals
  • Record Contains date, time, rate, total, grand total, and log number

Environmental

  • Operating & storage: -40° to 75° C
  • Backlight deactivated below temperatures ≈ -20°C
  • Relative Humidity: 0 to 90% non-condensing
  • Printed circuit boards are conformally coated

Connections

  • Screw terminals accept 12 to 22 AWG wire

Enclosure

  • NEMA 4X, IP68 Explosion-proof die cast aluminum, 0.30% max copper content, corrosion resistant epoxy coating
  • Color: Blue
  • Window: Glass
  • Three 3/4" NPT threaded conduit openings
  • One 3/4" NPT nickel plated brass conduit plug with 12 mm hex key fitting installed

Mounting

  • May be mounted directly to conduit. Two slotted flanges for wall mounting or NPS 1-1/2" to 2-1/2" or DN 40 to 65 mm pipe mounting

Overall Dimensions (W x H x D)

  • 5.65" x 5.25" x 4.86" (144 mm x 133 mm x 124 mm)

Weight

  • 5.00 lb (80 oz., 2.27 kg)

Warranty

  • 3 Years Parts and Labor
show more