Price
Request a Quote
Stock
 Call for Pricing & Availablility 
The TT810 loop-powered transmitter receives and measures signals from thermocouples and sends an output current of 4-20 mA which is directly proportional to the thermocouple millivolt input. 
The TT810 transmitter accepts thermocouple sensor types J, K, T, or E. The wide temperature range and stocked availability make the TT810 an excellent choice for temperature signal transmission. 
It is factory calibrated and designed for highest performance and lowest cost. Precision 20-turn potentiometers allow fine adjustment of ZERO and SPAN. TT810 units fit into industry standard connection heads.
Features- 2-wire loop-powered 4-20 mA output
 - Linearized output to voltage
 - Input T/C with cold junction compensation
 - Analog design, potentiometer adjustable
 - Factory calibrated for fixed range
 - Metal housing
 - Fits Standard heads
 
Specifications
Accuracy
- 0.15 % of Full Scale (Includes Effects of Linearity, Hysteresis & Repeatability)
 
Adjustment Type
- Factory Calibrated for Fixed Range
 
Enclosure Finish
- Enamel Painted
 
Enclosure, Body Material
- Die Cast Zinc
 
Operating Temperature
- -40° to 80° C (-40° to 176° F)
 
Output
- 4-20 mA Loop-Powered
 
Power Supply
- 12-32 Vdc, Polarity Protected
 
Power Supply Effect
- 0.02 %/V
 
Resistance
- Sensor Lead Resistance: 10 kΩ, max.
 
Sensor, Probe Connection
- 2-Wire
 
Sensor, Probe Type
- E Thermocouple
 - J Thermocouple
 - K Thermocouple
 - T Thermocouple
 
Span & Zero Adjustments
- 20-Turn Potentiometer, ± 10 % for Zero & Span
 
Storage Temperature
- -40° to 80° C (-40° to 176° F)
 
Temperature Range
- -50° to 1,200° C (-58° to 2,192° F)
 
Thermal Drift
- Span & Zero (Including Cold Junction Drift): ± 0.01 % of Full Scale/°C
 
Update Time
- Warm-Up: 30 seconds