RS89 Spring Loaded Sanitary RTD
Brand: Intempco Controls, IncSpecifications
- Sanitary 3-A qualified
 
Specifications
Approvals & Certifications
- 3-A Sanitary 74-03
 
Cable Material
- Polyolefin Shrink over Stainless Steel Armor
 - PVC
 - Teflon
 - Teflon Shrink over Stainless Steel Armor
 
Conduit Connection
- 1/2" NPT
 - 3/4" NPT
 
Diameter
- Probe: 0.236" (6 mm)
 - Probe: 1/4" (6.35 mm)
 
Enclosure, Body Material
- 316 Stainless Steel
 - 316L Stainless Steel
 - Bakelite
 - Cast Stainless Steel
 - Polypropylene
 
Environmental Protection
- IP67 Hermetically Sealed
 - NEMA 6P Hermetically Sealed
 
Instrument Connection
- 1/2" NPS Male
 - 1/2" NPT Male
 
Insulation Resistance
- > 100 MΩ at 100 Vdc Lead Wire to Sheath at 25° C (77° F)
 
Operating Pressure
- Sensor psig: 500 (kPa: 3,447, bar: 34.47)
 
Operating Temperature
- -50° to 125° C (-58° to 257° F)
 
RTD Type
- Pt100 DIN EN 60751, α = 0.00385° C⁻¹, Class AA, A, B, C
 
Sensor, Probe Connection
- 2-Wire Single, Dual
 - 3-Wire Single, Dual
 - 4-Wire Single
 
Sensor, Probe Material
- 316 Stainless Steel
 - 316L Stainless Steel
 
Sensor, Probe Type
- RTD
 
Storage Temperature
- -50° to 125° C (-58° to 257° F)
 
Temperature Range
- Sensor: -200° to 600° C (-328° to 1,112° F)
 
Tri-Clamp Connection
- 1-1/2" Hygienic Clamp Union
 - 2" Hygienic Clamp Union
 
Wetted Materials
- 316 Stainless Steel
 - 316L Stainless Steel