F043 Safe Area / Intrinsically Safe Temperature Monitor
Brand: Precision Digital CorporationThe F043 is a versatile temperature indicator with continuous temperature monitoring feature.
It has one low temperature and one high temperature alarm value.
If desired, an ignore (delay) function can be set up to allow for an incorrect temperature for a certain period of time.
The configuration of the Span, off-set and number of decimals is done through software functions, without any sensitive DIP-switches or trimmers.
Features- Displays actual temperature and alarm values
- Two alarm values can be entered: low and high temperature alarm
- Large 17 mm (0.67”) digits
- Red flashing LED backlight in case of a temperature alarm
- Selectable on-screen engineering units: °C - °F - K
- Temperature input signals: PT100 - 2, 3 or 4 wire and (0)4 - 20 mA
- One free configurable alarm output
- Loop or battery powered, 8-30 VDC or 115-230 VAC power supply
- Sensor supply 8.2 / 12 / 24 VDC
- Auto backup of all settings
- Explosion/flame proof available, according ATEX/IECEx
Advantages
- Robust aluminum or stainless steel 316L field enclosure (IP65, IP67 / NEMA Type4X). It is so rugged, a truck can even stand on it!
- Intrinsically Safe available - ATEX, IECEx and CSA approval for gas and dust applications
- Familiar easy operation with the Fluidwell "Know one, know them all" configuration structure, saving time, cost and aggravation
- Very diverse mounting possibilities: walls, pipes, panels or directly onto outdor sensors
Displaying prices & availability for Ohio, United States 43201 in USD. Change location.
Models matching criteria: 3,686
- Input - 4-20 mA
- Enclosure - GRP, Wall Mount, Cable Entry: 2 x Ø 16 mm & 1 x Ø 20 mm
- Output Options - One Passive Transistor Output - Standard Configuration
- Power Supply - 115-230 Vac + Sensor Supply
- Hazardous Area - Safe Area Only
- Relay - No Options
Call for Pricing & Availablility
Does not ship to OH, United States
- Input - PT100 Input
- Enclosure - GRP, Wall Mount, Cable Entry: 1 x Ø 22 mm
- Output Options - One Passive Transistor Output - Standard Configuration
- Power Supply - Basic Power Supply 8-30 Vdc
- Hazardous Area - EExd Enclosure - 3 Micro-Switch Keys
- Relay - No Options
Call for Pricing & Availablility
Does not ship to OH, United States
- Input - 0-10 Vdc
- Enclosure - Aluminum, Wall Mount, Cable Entry: 1 x .5” NPT
- Output Options - One Active Transistor Output
- Power Supply - 24 Vac/dc + Sensor Supply
- Hazardous Area - Safe Area Only
- Relay - No Options
Call for Pricing & Availablility
Does not ship to OH, United States
- Input - PT100 Input
- Enclosure - GRP, Wall Mount, Cable Entry: 1 x Ø 22 mm
- Output Options - One Passive Transistor Output - Standard Configuration
- Hazardous Area - Safe Area Only
- Relay - No Options
Call for Pricing & Availablility
Does not ship to OH, United States
- Input - 4-20 mA
- Enclosure - Panel Mount, GRP
- Output Options - One Passive Transistor Output - Standard Configuration
- Power Supply - Basic Power Supply 8-30 Vdc
- Hazardous Area - Safe Area Only
- Relay - Backlight
Call for Pricing & Availablility
Does not ship to OH, United States
- Input - 4-20 mA
- Enclosure - Aluminum, Wall Mount, Cable Entry: 1 x M20
- Output Options - One Passive Transistor Output - Standard Configuration
- Power Supply - 16-30 Vdc + Sensor Supply
- Hazardous Area - EExd Enclosure - 3 Micro-Switch Keys
- Relay - Backlight
Call for Pricing & Availablility
Does not ship to OH, United States
- Input - PT100 Input
- Enclosure - GRP, Wall Mount, Cable Entry: 2 x Ø 20 mm
- Output Options - One Passive Transistor Output - Standard Configuration
- Power Supply - Lithium Battery Powered
- Relay - No Options
Call for Pricing & Availablility
Does not ship to OH, United States
- Input - 4-20 mA
- Enclosure - Panel Mount, GRP
- Output Options - One Passive Transistor Output - Standard Configuration
- Power Supply - Lithium Battery Powered
- Relay - Backlight
Call for Pricing & Availablility
Does not ship to OH, United States
- Input - PT100 Input
- Enclosure - GRP, Wall Mount, Cable Entry: 6 x Ø 12 mm
- Output Options - One Passive Transistor Output - Standard Configuration
- Power Supply - Basic Power Supply 8-30 Vdc
- Hazardous Area - EExd Enclosure - 3 Micro-Switch Keys
- Relay - No Options
Call for Pricing & Availablility
Does not ship to OH, United States
- Input - 0-10 Vdc
- Enclosure - Aluminum, Wall Mount, Cable Entry: 1 x M20
- Output Options - One Passive Transistor Output - Standard Configuration
- Power Supply - Basic Power Supply 8-30 Vdc
- Hazardous Area - Intrinsically Safe According ATEX, IECEx, CSA c-us, & FM
- Relay - Backlight
Call for Pricing & Availablility
Does not ship to OH, United States
- Input - 4-20 mA
- Enclosure - Panel Mount, GRP
- Output Options - One Passive Transistor Output - Standard Configuration
- Power Supply - 115-230 Vac + Sensor Supply
- Hazardous Area - EExd Enclosure - 3 Micro-Switch Keys
- Relay - Backlight
Call for Pricing & Availablility
Does not ship to OH, United States
- Input - 4-20 mA
- Enclosure - Aluminum, Wall Mount, Cable Entry: 2 x PG9 + 1 x M20
- Output Options - One Passive Transistor Output - Standard Configuration
- Power Supply - 115-230 Vac + Sensor Supply
- Hazardous Area - EExd Enclosure - 3 Micro-Switch Keys
- Relay - Backlight
Call for Pricing & Availablility
Does not ship to OH, United States
- Input - 0-10 Vdc
- Enclosure - Aluminum, Wall Mount, Cable Entry: 1 x .5” NPT
- Output Options - One Passive Transistor Output - Standard Configuration
- Power Supply - 115-230 Vac + Sensor Supply
- Hazardous Area - EExd Enclosure - 3 Micro-Switch Keys
- Relay - No Options
Call for Pricing & Availablility
Does not ship to OH, United States
- Input - 0-10 Vdc
- Enclosure - Aluminum, Wall Mount, Cable Entry: 1 x M20
- Output Options - One Mechanical Relay Output
- Power Supply - 24 Vac/dc + Sensor Supply
- Hazardous Area - Safe Area Only
- Relay - No Options
Call for Pricing & Availablility
Does not ship to OH, United States
- Input - 0-10 Vdc
- Enclosure - GRP, Wall Mount, Cable Entry: 1 x Ø 22 mm
- Output Options - One Passive Transistor Output - Standard Configuration
- Power Supply - Basic Power Supply 8-30 Vdc
- Hazardous Area - Intrinsically Safe According ATEX, IECEx, CSA c-us, & FM
- Relay - No Options
Call for Pricing & Availablility
Does not ship to OH, United States
- Input - 4-20 mA
- Enclosure - Aluminum, Wall Mount, Cable Entry: 1 x .5” NPT
- Output Options - One Mechanical Relay Output
- Hazardous Area - EExd Enclosure - 3 Micro-Switch Keys
- Relay - No Options
Call for Pricing & Availablility
Does not ship to OH, United States
- Input - 0-10 Vdc
- Enclosure - GRP, Wall Mount, Cable Entry: 1 x Ø 22 mm
- Output Options - One Passive Transistor Output - Standard Configuration
- Power Supply - Lithium Battery Powered - Intrinsically Safe
- Hazardous Area - EExd Enclosure - 3 Micro-Switch Keys
- Relay - Backlight
Call for Pricing & Availablility
Does not ship to OH, United States
- Input - 4-20 mA
- Enclosure - GRP, Wall Mount, Cable Entry: 2 x Ø 16 mm & 1 x Ø 20 mm
- Output Options - One Passive Transistor Output - Standard Configuration
- Power Supply - 16-30 Vdc + Sensor Supply
- Hazardous Area - EExd Enclosure - 3 Micro-Switch Keys
- Relay - No Options
Call for Pricing & Availablility
Does not ship to OH, United States
- Input - 0-10 Vdc
- Enclosure - GRP, Wall Mount, Cable Entry: 2 x Ø 16 mm & 1 x Ø 20 mm
- Output Options - One Active Transistor Output
- Power Supply - 24 Vac/dc + Sensor Supply
- Hazardous Area - Safe Area Only
- Relay - Backlight
Call for Pricing & Availablility
Does not ship to OH, United States
- Input - 0-10 Vdc
- Enclosure - Aluminum, Wall Mount, Cable Entry: 1 x .5” NPT
- Output Options - One Active Transistor Output
- Power Supply - 115-230 Vac + Sensor Supply
- Hazardous Area - Safe Area Only
- Relay - Backlight
Call for Pricing & Availablility
Does not ship to OH, United States
- Input - 0-10 Vdc
- Enclosure - Aluminum, Wall Mount, Cable Entry: 1 x .5” NPT
- Output Options - One Passive Transistor Output - Standard Configuration
- Power Supply - 24 Vac/dc + Sensor Supply
- Hazardous Area - Safe Area Only
- Relay - No Options
Call for Pricing & Availablility
Does not ship to OH, United States
- Input - 0-10 Vdc
- Enclosure - Aluminum, Wall Mount, Cable Entry: 2 x M20
- Output Options - One Passive Transistor Output - Standard Configuration
- Power Supply - 115-230 Vac + Sensor Supply
- Hazardous Area - Safe Area Only
- Relay - Backlight
Call for Pricing & Availablility
Does not ship to OH, United States
- Input - PT100 Input
- Enclosure - Aluminum, Wall Mount, Cable Entry: 2 x 1/2” NPT
- Output Options - One Active Transistor Output
- Hazardous Area - Safe Area Only
- Relay - Backlight
Call for Pricing & Availablility
Does not ship to OH, United States
- Input - 4-20 mA
- Enclosure - Aluminum, Wall Mount, Cable Entry: 4 x M20
- Output Options - One Passive Transistor Output - Standard Configuration
- Power Supply - 24 Vac/dc + Sensor Supply
- Hazardous Area - EExd Enclosure - 3 Micro-Switch Keys
- Relay - No Options
Call for Pricing & Availablility
Does not ship to OH, United States
- Input - 4-20 mA
- Enclosure - Aluminum, Wall Mount, Cable Entry: 3 x .5” NPT
- Output Options - One Passive Transistor Output - Standard Configuration
- Power Supply - Basic Power Supply 8-30 Vdc
- Hazardous Area - EExd Enclosure - 3 Micro-Switch Keys
- Relay - No Options
Call for Pricing & Availablility
Does not ship to OH, United States
- Input - 4-20 mA
- Enclosure - GRP, Wall Mount, Cable Entry: 3 x Ø 22 mm
- Output Options - One Passive Transistor Output - Standard Configuration
- Power Supply - Basic Power Supply 8-30 Vdc
- Hazardous Area - Intrinsically Safe According ATEX, IECEx, CSA c-us, & FM
- Relay - No Options
Call for Pricing & Availablility
Does not ship to OH, United States
- Input - 4-20 mA
- Enclosure - GRP, Wall Mount, Cable Entry: 6 x Ø 12 mm
- Output Options - One Passive Transistor Output - Standard Configuration
- Power Supply - Basic Power Supply 8-30 Vdc
- Hazardous Area - Intrinsically Safe According ATEX, IECEx, CSA c-us, & FM
- Relay - No Options
Call for Pricing & Availablility
Does not ship to OH, United States
- Input - 4-20 mA
- Enclosure - GRP, Wall Mount, Flat Bottom, Cable Entry: No Holes
- Output Options - One Passive Transistor Output - Standard Configuration
- Power Supply - Basic Power Supply 8-30 Vdc
- Hazardous Area - Intrinsically Safe According ATEX, IECEx, CSA c-us, & FM
- Relay - Backlight
Call for Pricing & Availablility
Does not ship to OH, United States
- Input - 4-20 mA
- Enclosure - Aluminum, Wall Mount, Cable Entry: 1 x M20
- Output Options - One Passive Transistor Output - Standard Configuration
- Power Supply - Basic Power Supply 8-30 Vdc
- Hazardous Area - Safe Area Only
- Relay - Backlight
Call for Pricing & Availablility
Does not ship to OH, United States
- Input - 4-20 mA
- Enclosure - Aluminum, Wall Mount, Cable Entry: 2 x PG9 + 1 x M20
- Output Options - One Active Transistor Output
- Hazardous Area - Safe Area Only
- Relay - No Options
Call for Pricing & Availablility
Does not ship to OH, United States
- Input - 0-10 Vdc
- Enclosure - Aluminum, Wall Mount, Cable Entry: 1 x M20
- Output Options - One Mechanical Relay Output
- Power Supply - 24 Vac/dc + Sensor Supply
- Hazardous Area - EExd Enclosure - 3 Micro-Switch Keys
- Relay - Backlight
Call for Pricing & Availablility
Does not ship to OH, United States
- Input - PT100 Input
- Enclosure - GRP, Wall Mount, Cable Entry: 3 x Ø 22 mm
- Output Options - One Passive Transistor Output - Standard Configuration
- Hazardous Area - Safe Area Only
- Relay - Backlight
Call for Pricing & Availablility
Does not ship to OH, United States
- Input - 4-20 mA
- Enclosure - Aluminum, Wall Mount, Cable Entry: 1 x M20
- Output Options - One Passive Transistor Output - Standard Configuration
- Power Supply - 115-230 Vac + Sensor Supply
- Relay - Backlight
Call for Pricing & Availablility
Does not ship to OH, United States
- Input - 0-10 Vdc
- Enclosure - Aluminum, Wall Mount, Cable Entry: 3 x .5” NPT
- Output Options - One Passive Transistor Output - Standard Configuration
- Power Supply - 16-30 Vdc + Sensor Supply
- Hazardous Area - EExd Enclosure - 3 Micro-Switch Keys
- Relay - Backlight
Call for Pricing & Availablility
Does not ship to OH, United States
- Input - PT100 Input
- Enclosure - Aluminum, Wall Mount, Cable Entry: 6 x M12
- Output Options - One Passive Transistor Output - Standard Configuration
- Power Supply - Basic Power Supply 8-30 Vdc
- Hazardous Area - Intrinsically Safe According ATEX, IECEx, CSA c-us, & FM
- Relay - No Options
Call for Pricing & Availablility
Does not ship to OH, United States
- Input - 0-10 Vdc
- Enclosure - GRP, Wall Mount, Flat Bottom, Cable Entry: No Holes
- Output Options - One Active Transistor Output
- Hazardous Area - Safe Area Only
- Relay - Backlight
Call for Pricing & Availablility
Does not ship to OH, United States
- Input - 0-10 Vdc
- Enclosure - Aluminum, Wall Mount, Cable Entry: 2 x M16 + 1 x M20
- Output Options - One Passive Transistor Output - Standard Configuration
- Power Supply - 24 Vac/dc + Sensor Supply
- Relay - Backlight
Call for Pricing & Availablility
Does not ship to OH, United States
- Input - 4-20 mA
- Enclosure - Aluminum, Wall Mount, Cable Entry: 1 x .5” NPT
- Output Options - One Mechanical Relay Output
- Power Supply - 115-230 Vac + Sensor Supply
- Relay - No Options
Call for Pricing & Availablility
Does not ship to OH, United States
- Input - 4-20 mA
- Enclosure - Aluminum, Wall Mount, Cable Entry: 2 x M16 + 1 x M20
- Output Options - One Mechanical Relay Output
- Relay - No Options
Call for Pricing & Availablility
Does not ship to OH, United States
- Input - PT100 Input
- Enclosure - Aluminum, Wall Mount, Cable Entry: 2 x M20
- Output Options - One Passive Transistor Output - Standard Configuration
- Power Supply - Basic Power Supply 8-30 Vdc
- Hazardous Area - Intrinsically Safe According ATEX, IECEx, CSA c-us, & FM
- Relay - No Options
Call for Pricing & Availablility
Does not ship to OH, United States
Specifications
Display
- High intensity reflective numeric and alphanumeric LCD, UV-resistant
- 90 x 40 mm (3.5” x 1.6”)
- Seven 17 mm (0.67”) and eleven 8 mm (0.31”) digits. Various symbols and measuring units
- User definable: fast, 1sec , 3sec, 15sec, 30sec, off
Approvals & Certifications
- RoHS
- IP & NEMA
- ATEX
- CE
- CSA
- EMC
- FM
- IEC
- IECEx
Power Requirement
- Type PB: Long life Lithium battery
- Type PC: Intrinsically Safe long life lithium battery
- Type PD: 16-30 VDC. power consumption max. 1 W
- Type PF: 24 VAC / DC ± 10%. Power consumption max. 15 W
- Type PL: Input loop powered from sensor signal 4-20 mA (type “A”)
- Type PM: 115-230 VAC ± 10%. Power consumption max. 15 W
- Type PX: 8-30 VDC. Power consumption max. 0.3 W
- Type ZB: 20-30 VDC ± 10%. Power consumption max. 1 W. With type PF / PM: internally powered
Enclosure
- GRP, Aluminum or Stainless steel 316L wall / field mount
- Panel mount
Operating Temperature
- -40° to 80° C (-40° to 176° F)
Terminal Connection
- Removable plug-in terminal strip. Wire max. 1.5 mm2 and 2.5 mm2
Environmental Protection
- IP65
- IP67
- NEMA 4X
Resolution
- 16-bits
Accuracy
- Error < 0.01 mA / ± 0.05 % of FSO. Low level cut-off programmable
Communication
- Modbus
- HART
Signal Inputs
- PT100 - 2, 3 or 4 wire PRTD sensor
- (0)4 – 20 mA
Signal Outputs
- Alarm outputs - Function: Configurable alarm output for high, low or both combined temperature alarm
- Alarm outputs - Type: One passive NPN transistor, active PNP transistor or isolated electro-mechanical relay
- For Applications Where Continuous Temperature Measurement and Monitoring Is Important Without Signal Re-transmission
- For Field Mount Indicators in Safe and Hazardous Area Applications. Especially in Harsh Weather Conditions Like Rain, Snow, Sandy Deserts, Salty Atmospheres and Temperatures Between -40° to +80° C (-40° to 176° F)